The Industry’s Most Efficient High-Capacity Tabletop Sterilizer

A proven advancement in RapidCycle sterilization, the RH-Pro11 sterilizer will raise your level of sterilization efficiency. Using Cutting-Edge HVHA (High-Velocity Hot Air)
technology, the RH-Pro11 provides the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no lengthy drying cycle with
longer instrument life free of corrosion.

For Healthcare, the RH-Pro11 can Eliminate “Immediate-Use” Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny. With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.

RH-Pro11 Installation and Operation Video
Cassette Wrapping and Taping Instructions

With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.

The RH-PRO11 Advantage

•     FDA-Cleared 6 Minute Sterilization Cycles (Unwrapped)
•     FDA-Cleared 12 Minute Sterilization Cycles (Wrapped)
•     Large Table-Top Capacity (2295 Cubic Inches)
•     Uses 65% Less Energy Than Steam
•     Non-Corrosive Sterilizer Environment
•     Full 3-Year Warranty
•     Waterless Sterilization with No Chemicals
•     Greater Capacity — Four Large Trays

Unit Size (OD) 21.5″ W x 22.5″ D x 19.5″ H
546.1 mm x 572 mm x 495 mm
Chamber Size (ID) 11”W x 17.75”D x 11.75”H,
279mm x 433mm x 299mm
Weight 91 lbs (41 Kg)
Instrument Tray 9”W x 15”D x 1”H,
229mm x 381mm x 28mm
Electrical 110-120V, 60Hz, 1400 Watts warm up,
300 Watts operating
220-240V, 60Hz, 1400 Watts warm up,
300 Watts operating
Sterilization Temperature 375°F (190°C)
320°F (160°C)
300°F (149°C)
280°F (138°C)
Warranty Three years (parts and labor)
Safety Meets Requirements of U.S. Electrical Safety Standards.

Sterilization Cycle Times

Total Sterilization Processing Times 375°F

  • Unwrapped Instruments – 14 Minutes
  • Handpieces 16 Minutes
  • Wrapped / Pouched Instruments – 21 Minutes
  • Wrapped Cassettes 40 Minutes

Total Sterilization Processing Time Low-Temperature

  • 320°F – 42 Minutes
  • 300°F – 58 Minutes
  • 280°F – 126 Minutes

The RapidHeat RH-Pro Advantage

No Dry Cycle

Improves Instrument Turnaround Time and removes the threat of environmental contamination and instrument corrosion from wet instruments.

No Water

Saves Time & Improves Patient Safety – With no water required, the potential for contamination from improperly cleaned water reservoirs is eliminated.

No Extensive Maintenance

There is no costly and time-consuming maintenance – Only a few minutes a week is needed to ensure the safe and effective operation of an RH-Pro Sterilizer.

Low-Temperature Cycle Options

CPAC has created low-temperature cycles to process devices/instruments that are known or could potentially become degraded by RapidHeat’s standard High-Temperature cycle of 375°F.

  • Three temperature cycles: 320°F (160°C), 300°F (149°C), 280°F (138°C)
  • Choice of three low-temperature cycles
  • Allows user to validate and verify 12-log kill sterilization
  • Eliminates heat-sensitive device concerns
  • Time/temperature profiles equivalent to steam

Unlike traditional Dry Heat, RapidHeat is an advanced thermal sterilization technology circulating high velocity hot air in a sealed chamber at 200 to 300 air exchanges per minute.